PLUR - Central locking rods electronically locked

PLUR

The PLUR lock enables the locking of several superimposed drawers with a central locking bar.

The assembly takes place at the top of the lid of the furniture on the inside. With wide drawers, a PLUR SECONDARY lock can be connected with a cable, which then opens at the same time.

Due to the integrated spring, the drawer does not necessarily have to be closed to lock the lock.

The RFID reading range and battery life depend on the technology used and the quality of the RFID key units (cards, fobs, stickers or bracelets) or battery used.

PLUR blum

With the PLUR blum adapter plate PLUR locks can be connected directly to the blum Cabloxx system. The adapter plate is designed so that it is placed flush with the front and sides and screwed together with the lock.

The products differ only by the pre-attached adapter plate.

PLUR 125

  • Opens and locks with the key (key card, key fob or wristband)
  • On request, the lock can also close automatically after 3 seconds
  • Access control for up to 49 keys
  • EM4102/ EM4200 RFID Technology
  • Programming instruction RFID

PLUR 13

  • Opens and locks with the key (key card, key fob or wristband)
  • On request, the lock can also close automatically after 3 seconds
  • Mifare ISO 14443A RFID Technology
  • Programming instruction RFID

PLUR BT

Accessories

PLUR SLAVE

The PLUR SLAVE is a central locking lock which can be connected directly to the rear of the PLUR 125, PLUR 13 or PLUR BT and thus enables the simultaneous opening of very wide drawers. The cable length is 1.5 m. Alternatively, any other microprocessor may be used for control.

The following assignment applies to the 1.5 m cable supplied:

  • White – control line, LOW=open, HIGH=close
  • black in the middle: Plus 3 V
  • black outside: minus GNDB

PLUR 3 V / 12 V DC

PLUR 3 V

The PLUR 3 V is operated with a voltage of 2-3 V DC. Usually a double throw switch or a relay is used.

Connection:

  • blue– GND / Minus
  • Brown– open
  • black– close

PLUR 12 V

The PLUR 12 V is operated with a voltage of 8-16 V DC. Usually a double throw switch or a relay is used.

Connection:

  • blue– GND / Minus
  • Brown– open
  • black– close